ARA Manufacture Mobile Logo
Mobile Menu

Products

Securaguard

View the Sealeck Securaguard range of High Security Products

View Products

Renlita

View the range of Renlita doors.

View Products
<
>
Browse By Brand

Find The Right Products For Your Project

What Are You Working On?

  • Security Systems
  • Restaurants
  • Residential Projects
  • Shopping Centres
  • Showrooms
  • Warehouses
  • Ticket Windows
  • Storefronts
  • Prison Systems
  • Power Stations
  • Custom Projects
  • Commercial Projects
  • Chemical Plants
  • Embassys
  • Garages
  • Locomotives
  • Industrial Projects
  • Hangars
  • Biocontainment Systems
Back

I'm working on
A Custom Project
& I need the following items:

Add products & capabilities to the list on the left the select Find Products, or search by product name.

What Type Of Products Do You Need?

Set one or more product categories

  • Shutters
  • Screens
  • Pass Through Units
  • Windows...
    • Vision Panels
    • Window Units
  • Walls
  • Doors...
    • Door Frames
    • Door Sets
    • Folding Doors
    • Hinge Doors
    • Overhead Doors
    • Sliding Doors
  • Glazings
  • Hinges
  • Grilles
  • Counters

What Does Your Need To Do?

ARA Manufacture's product range provides a wide range of capabilities & options. Select the capability you require for your & the degree you require.

  • Bullet Resistance
  • Intruder Resistance
  • Physical Containment
  • Fire Resistance
  • Blast Protection
  • Wind Loading
  • Biosafety Level
Select a capability from the list on the left to get started.

Bullet Resistance

Bullet Resistance is categorised according to BULLET RESISTANT STANDARD AS2343 1997

G0

  • Calibre: 9mm Parabellum
  • Ammunition: Mk22 7.4 gram bullet
  • Measured Velocity within 2.5m of target: 405m/s +/- 15
  • Minimum Range: 3
  • Number Of Strikes: 3

G1

  • Calibre: 357 Magnum
  • Ammunition: 10.2 gram semi jacket soft point
  • Measured Velocity within 2.5m of target: 450m/s +/- 15
  • Minimum Range: 3
  • Number Of Strikes: 3

G2

  • Calibre: .44 Magnum
  • Ammunition: 15.6 gram semi jacket soft point
  • Measured Velocity within 2.5m of target: 480m/s +/- 15
  • Minimum Range: 3
  • Number Of Strikes: 3

R1

  • Calibre: 5.56mm
  • Ammunition: M193 5.56mm 3.6 gram FMJ
  • Measured Velocity within 2.5m of target: 980m/s +/- 15
  • Minimum Range: 10
  • Number Of Strikes: 3

R2

  • Calibre: 7.62mm
  • Ammunition: NATO 9.3 gram FMJ
  • Measured Velocity within 2.5m of target: 850m/s +/- 15
  • Minimum Range: 10
  • Number Of Strikes: 3

S0

  • Calibre: 12 Gauge (Full Choke)
  • Ammunition: 70mm Case 32 gram SG shot
  • Measured Velocity within 2.5m of target: 400m/s +/- 15
  • Minimum Range: 3
  • Number Of Strikes: 2

S1

  • Calibre: 12 Gauge (Full Choke)
  • Ammunition: 70mm Case 28.5 gram SG shot
  • Measured Velocity within 2.5m of target: 450m/s +/- 15
  • Minimum Range: 3
  • Number Of Strikes: 2

Intruder Resistance

Intruder Resistance is categorised according to INTRUDER RESISTANT STANDARD AS555

Lv1

    One man using common hand tools.
    Common Hand Tools are described as, axes, sledges, screw drivers, hammers, chisels, pry bars and wedges etc, none of which are to exceed 1.5 metres in length or 3.6 kg in weight.

Lv2

    Two men using common hand tools
    Common Hand Tools are described as, axes, sledges, screw drivers, hammers, chisels, pry bars and wedges etc, none of which are to exceed 1.5 metres in length or 3.6 kg in weight.

Lv3

    One man using common hand tools and power tools.
    Common Hand Tools are described as, axes, sledges, screw drivers, hammers, chisels, pry bars and wedges etc, none of which are to exceed 1.5 metres in length or 3.6 kg in weight.
    Power Tools are described as, hammer drills and drills to a maximum of 25mm chuck size, and power saws abrasive disc cutters to a maximum of 200mm dia, and chainsaws or sabre saws.

Lv4

    Two men using common hand tools and power tools.
    Common Hand Tools are described as, axes, sledges, screw drivers, hammers, chisels, pry bars and wedges etc, none of which are to exceed 1.5 metres in length or 3.6 kg in weight.
    Power Tools are described as, hammer drills and drills to a maximum of 25mm chuck size, and power saws abrasive disc cutters to a maximum of 200mm dia, and chainsaws or sabre saws.

Lv5

    Two men using hydraulic tools and common hand tools.
    Common Hand Tools are described as, axes, sledges, screw drivers, hammers, chisels, pry bars and wedges etc, none of which are to exceed 1.5 metres in length or 3.6 kg in weight.

Lv6

    Two men using common hand tools and Gas oxygen cutting equipment.
    Common Hand Tools are described as, axes, sledges, screw drivers, hammers, chisels, pry bars and wedges etc, none of which are to exceed 1.5 metres in length or 3.6 kg in weight.

Physical Containment

Physical Containment is categorised according to AS-NZS 2243-3: SAFETY IN LABORATORIES

PC1

    A Physical Containment Level 1 laboratory is suitable for work with microorganisms where the hazard levels are low, and where laboratory or facility personnel can be adequately protected by standard laboratory practice.
    The organisms used should generally be classified as Risk Group 1. Specimens that have been inactivated or fixed may be handled in PC1 facilities.

PC2

    A Physical Containment Level 2 laboratory is suitable for work with material likely to contain microorganisms that are classified as Risk Group 2 microorganisms.
    If working with specimens containing microorganisms transmissible by the respiratory route or if the work produces a significant risk to humans or the environment from the production of infectious aerosols, a biological safety cabinet must be used.

PC3

    A Physical Containment Level 3 laboratory is suitable for work with carried out with microorganisms or material likely to contain microorganisms that are classified as Risk Group 3 microorganisms.
    A PC3 laboratory or facility provides additional building features and services to minimise the risk of infection to individuals, the community and the environment.

PC4

    A Physical Containment Level 4 laboratory is suitable for work with microorganisms classified as Risk Group 4 microorganisms.
    A PC4 laboratory or facility is situated in a building separate from other laboratories facilities or constructed as an isolated area within a building.

Fire Resistance

Fire Resistance is categorised according to Australian Fire standard AS1530.4 and Australian fire door standard AS1905.1

-/120/30

    120 minute fire integrity – The ability to resist flames & hot gas.
    30 minute fire insulation –  the ability to resist insulated heat (heat transfer) where the temperature cannot increase more than 180 deg C at any one point or 140 deg C on average over the ambient / starting temperature during a fire test.

-/180/30

    180 minute fire integrity – The ability to resist flames & hot gas.
    30 minute fire insulation –  the ability to resist insulated heat (heat transfer) where the temperature cannot increase more than 180 deg C at any one point or 140 deg C on average over the ambient / starting temperature during a fire test.

-/240/30

    240 minute fire integrity – The ability to resist flames & hot gas.
    30 minute fire insulation –  the ability to resist insulated heat (heat transfer) where the temperature cannot increase more than 180 deg C at any one point or 140 deg C on average over the ambient / starting temperature during a fire test.

Blast Protection

72

    Capable of withstanding up to 72kPa peak reflected overpressure lasting 100ms.

122

    Capable of withstanding up to 122kPa peak reflected overpressure lasting 100ms.

152

    Capable of withstanding up to 152kPa peak reflected overpressure lasting 100ms.

272

    Capable of withstanding up to 272kPa peak reflected overpressure lasting 100ms.

Wind Loading

Wind Loading is certified according to AS1170 & AS1250

0.5

    Capable of resisting a minimum wind loading of 0.5kPa.

Biosafety Level

BSL1

    This level is suitable for work involving well-characterized agents not known to consistently cause disease in healthy adult humans, and of minimal potential hazard to laboratory personnel and the environment.

BSL2

    Suitable for work involving agents of moderate potential hazard to personnel and the environment, including various bacteria and viruses that cause only mild disease to humans, or are difficult to contract via aerosol in a lab setting.

BSL3

    This level is applicable to clinical, diagnostic, teaching, research, or production facilities in which work is done with indigenous or exotic agents which may cause serious or potentially lethal disease after inhalation. It includes various bacteria, parasites and viruses that can cause severe to fatal disease in humans but for which treatments exist.

BSL4

    This level is required for work with dangerous and exotic agents that pose a high individual risk of aerosol-transmitted laboratory infections, agents which cause severe to fatal disease in humans for which vaccines or other treatments are not available.